Solar Submetering

Track solar production, allocate credits fairly, and comply with NEM 3.0. Understand exactly how your rooftop panels benefit each tenant.

Get Solar Metering Quote

Why Solar Submetering?

Under NEM 3.0, exported solar is worth a fraction of self-consumed solar — metering is what captures the difference

Production Monitoring

Real-time tracking of solar generation at the inverter level. Know exactly how much energy your panels produce, when they produce it, and catch underperformance early.

Consumption Tracking

Individual tenant consumption metering synced with solar production. Understand the net energy position of each unit in real-time.

Credit Allocation

Automated calculation and allocation of solar credits to tenants. Fair distribution based on lease terms, usage, or custom formulas.

Solar Metering Architecture

Production + Consumption = Net Position for each tenant

Solar Array
Rooftop / Carport
DC Power
Inverter
Production Meter
AC Power
Main Panel
Distribution
Unit A: +$45 credit
Unit B: +$38 credit
Unit C: +$52 credit
Common: +$28 credit

NEM 3.0 requires accurate time-of-use tracking. Solar production during peak hours is worth more than midday production. Our metering captures the value timing.

Why Metering Matters Under NEM 3.0

The value of solar shifted from "how much" to "when"

Midday Export

~$0.05

per kWh

When solar production peaks, grid is flooded — low value

Self-Consumed

$0.30+

per kWh avoided

Energy used on-site offsets full retail rate

The Math: Accurate metering lets you match solar production with tenant consumption in real-time, maximizing self-consumption vs. low-value exports.

Solar Metering Applications

Solutions for every property type with shared solar

Multifamily VNEM

Virtual Net Energy Metering allows apartment buildings to share solar benefits across all units — but requires accurate allocation metering.

  • Compliant VNEM credit allocation
  • Tenant billing integration
  • NEM 3.0 TOU compliance
  • Common area credit tracking

Commercial Solar

Multi-tenant commercial properties with rooftop solar need fair allocation between tenants with different operating hours and consumption patterns.

  • Tenant-specific credit calculation
  • Demand charge offset tracking
  • CAM allocation support
  • Landlord/tenant split accounting

Solar + Storage

Battery storage systems require metering to track charge/discharge cycles and attribute stored solar to the right time periods and tenants.

  • Battery state-of-charge tracking
  • Time-shift value calculation
  • Peak shaving documentation
  • Backup power allocation

Industrial Net Zero

Manufacturing and warehouse facilities pursuing net-zero goals need accurate production vs. consumption data for sustainability reporting.

  • Carbon offset documentation
  • ESG reporting data
  • Production efficiency metrics
  • Grid export verification

What NEM 3.0 Changed

Why accurate solar metering matters more than ever

Lower Export Values

In effect since April 2023, NEM 3.0 sharply cut export compensation. Exported solar earns roughly $0.05/kWh midday, against the $0.30+/kWh retail rate it offsets when self-consumed. Accurate metering is what lets you shift consumption to match production.

Solution: Real-time consumption matching to maximize on-site use

Time-of-Use Complexity

Solar production peaks at midday; TOU rates peak in evening. Without accurate timing data, you can't calculate true value or optimize battery dispatch.

Solution: 15-minute interval metering aligned with utility TOU periods

VNEM Allocation Disputes

Multifamily VNEM requires fair allocation of solar credits. Without metering, tenants dispute their share and landlords face audit exposure.

Solution: Transparent, metered allocation with audit-ready records

Underperformance Detection

Solar panels degrade, inverters fail, and shading changes. Without production monitoring, you lose money for months before anyone notices.

Solution: Production monitoring with alerts for underperformance

Utility Program Expertise

We navigate the solar programs at every Southern California utility

SCE (Southern California Edison)

LA, OC, Inland Empire

NEM 3.0 (Net Billing Tariff) with complex TOU rates. VNEM for multifamily and commercial solar sharing.

NEM 3.0 VNEM TOU-D-PRIME

SDG&E

San Diego County

TOU rates with significant peak/off-peak spreads. Accurate production timing matters for value capture under SDG&E's rate structures.

NEM 3.0 TOU Rates VNEM

LADWP

City of Los Angeles

LADWP has its own solar programs separate from CPUC rules. Different rates, different metering requirements.

Feed-in Tariff SOLAR Incentive Net Metering

Municipal Utilities

Various Cities

Burbank, Glendale, Pasadena, Anaheim, and Riverside have their own solar programs with unique requirements.

Varied Programs Local Incentives

Track where solar goes

Know when it's valuable

Allocate credits fairly

Maximize Your Solar Investment

Don't let solar production go unmeasured. Get accurate allocation, NEM 3.0 compliance, and transparent tenant billing.

Solar Production Assessment

Send us your solar system details and utility bills. We'll analyze your production, consumption patterns, and show how metering can increase ROI.

Request Assessment